current location:home pageProduct Center

63520T_F111A1 63620T_F111A3

Instructions Download>

Model

F111A1/F111A363520T/63620T

Inlet/outlet

2" M

Drain

1.5" M

Brine line connector

3/4"M

Mounting base

4" -8UN

Riser pipe

2" D-GB(Outer diameter63mm)

Flow rate

20m³/h

Filter tank

28"--40"

Water pressure

Up-flow

Water temperature

0.2-0.6MPa

Water turbidity

5-50℃

Inlet/outlet

5FTU

Ambient temperature

5℃--50℃

Relative humidity

≤95%25℃

Power adapter

Input AC100~240V/50~60HZ Output DC24V/1.5A


Product description

F111 Automatic Multiport Softener Valves

The F111A1 automatic multiport softener valve is timer clock type while the F111A3 is a meter type. Featuring a flow rate of 20m³/h, the F111A1/A3 is equipped with two valve cores, one controlling the inflow of water and brine, the other controlling outflow and drainage.

Product Characteristics

  • Simple structure and reliable sealing

    It adopts hermetic head faces with high degree pottery and corrosion resistance for opening and closing. It combines with Service, Backwash, Brine & Slow Rinse, Brine Refill and Fast Rinse.

  • No water passes the valve during regeneration in single tank type

  • Brine refill controlled by electronic ball valve

    During service, electronic ball valve will control to start the brine refill. In order to short the regeneration cycle time.

  • DF softener system can be changed to filtration system

    Block the brine line connector and remove the drain connector of 63520 to change the valve to filter valve 53520.

    Block the brine line connector and remove the drain connector of 63620 to change the valve to filter valve 53620.

  • Manual function

    Realize regeneration immediately by pushing “Manual/Return” at any time.

  • Long outage indicator

    If outage overrides 3 days, the time of day indicator “12:12” will flash to remind people to reset new time of day. The other set parameters do not need to reset. The process will continue to work after power on.

  • LED dynamic screen display

    The stripes on dynamic screen flash, they indicate the control valve is in service, otherwise, it is in regeneration cycle.

  • Buttons lock

    No operations to buttons on the controller within 1 minute, button lock indicator light on which represent buttons are locked. Before operation, press and hold the “Up” and “Down” buttons for 5 seconds to unlock. This function can avoid incorrect operation.

  • It can choose all models by program selection

    When all symbols light on, press and hold “Down” and Manual/Return buttons more than 2 seconds to enter the menu of valve model selection. Press “Up” and“Down” buttons to select the requested model, then press “Menu/Confirm” button to save the selection. Reconnect the power, the model will be showed on display board.

  • Interlock function

It has a function of interlock to realize only one valve in regeneration but the other valves are in service while several valves parallel in system. In multi-steps treatment systems such as RO pre-treatment, when several valves are in series, there is only one valve in regeneration or washing to ensure pass water all the times.